Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mikrochim Acta ; 189(12): 483, 2022 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-36446842

RESUMO

Fentanyl is a powerful synthetic opioid used to treat severe pain. New administration routes toward its illegal consumption for recreational purposes pose a growing threat to public health, either due to misuse or abuse of this substance. As a result, the rapid qualitative and quantitative determination of fentanyl in biofluids is of great interest. A novel enzymatic biosensor based on adsorptive-stripping cyclic voltammetry is proposed as a cost-effective, reliable, and efficient device for fentanyl determination in urine samples. Disposable screen-printed carbon electrodes modified with multi-walled carbon nanotubes and cytochrome c were used to develop the testing platform. The electrochemical behavior of fentanyl exhibited a well-defined anodic wave around 0.66 V vs. pseudo reference electrode. The experimental conditions were optimized to obtain the best analytical response, and linear regression analysis of increasing concentration standards was applied to estimate the performance parameters. The results suggest a simple method with a wide linearity range, high sensitivity, low limits of detection (0.086 µg/mL) and quantification, and satisfactory precision (2.9% RSD). The feasibility and applicability of the voltammetric approach were assessed by fentanyl-spiked urine samples by standard additions calibration curves in two levels of enrichment with an accuracy of 92% and 100%.


Assuntos
Técnicas Biossensoriais , Nanotubos de Carbono , Citocromos c , Fentanila , Eletrodos
2.
Sensors (Basel) ; 22(1)2021 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-35009837

RESUMO

The synthetic cathinones mephedrone (4-MMC) and 4-methylethcathinone (4-MEC) are two designer drugs that represent the rise and fall effect of this drug category within the stimulants market and are still available in several countries around the world. As a result, the qualitative and quantitative determination of 'legal highs', and their mixtures, are of great interest. This work explores for the first time the spectroelectrochemical response of these substances by coupling cyclic voltammetry (CV) with Raman spectroscopy in a portable instrument. It was found that the stimulants exhibit a voltammetric response on a gold screen-printed electrode while the surface is simultaneously electro-activated to achieve a periodic surface-enhanced Raman spectroscopy (SERS) substrate with high reproducibility. The proposed method enables a rapid and reliable determination in which both substances can be selectively analyzed through the oxidation waves of the molecules and the characteristic bands of the electrochemical SERS (EC-SERS) spectra. The feasibility and applicability of the method were assessed in simulated seized drug samples and spiked synthetic urine. This time-resolved spectroelectrochemical technique provides a cost-effective and user-friendly tool for onsite screening of synthetic stimulants in matrices with low concentration analytes for forensic applications.


Assuntos
Ouro , Análise Espectral Raman , Eletrodos , Reprodutibilidade dos Testes
3.
Sensors (Basel) ; 16(10)2016 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-27681735

RESUMO

A novel amperometric biosensor for the determination of Al(III) based on the inhibition of the enzyme superoxide dismutase has been developed. The oxidation signal of epinephrine substrate was affected by the presence of Al(III) ions leading to a decrease in its amperometric current. The immobilization of the enzyme was performed with glutaraldehyde on screen-printed carbon electrodes modifiedwith tetrathiofulvalene (TTF) and different types ofnanoparticles. Nanoparticles of gold, platinum, rhodium and palladium were deposited on screen printed carbon electrodes by means of two electrochemical procedures. Nanoparticles were characterized trough scanning electronic microscopy, X-rays fluorescence, and atomic force microscopy. Palladium nanoparticles showed lower atomic force microscopy parameters and higher slope of aluminum calibration curves and were selected to perform sensor validation. The developed biosensor has a detection limit of 2.0 ± 0.2 µM for Al(III), with a reproducibility of 7.9% (n = 5). Recovery of standard reference material spiked to buffer solution was 103.8% with a relative standard deviation of 4.8% (n = 5). Recovery of tap water spiked with the standard reference material was 100.5 with a relative standard deviation of 3.4% (n = 3). The study of interfering ions has also been carried out.

4.
Sensors (Basel) ; 15(2): 2232-43, 2015 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-25621602

RESUMO

This paper presents a chronoamperometric method to determine tungsten in water using screen-printed carbon electrodes modified with gold nanoparticles and cross linked alkaline phosphatase immobilized in the working electrode. Enzymatic activity over 2-phospho-l-ascorbic acid trisodium salt, used as substrate, was affected by tungsten ions, which resulted in a decrease of chronoamperometric current, when a potential of 200 mV was applied on 10 mM of substrate in a Tris HCl buffer pH 8.00 and 0.36 M of KCl. Calibration curves for the electrochemical method validation, give a reproducibility of 5.2% (n = 3), a repeatability of 9.4% (n = 3) and a detection limit of 0.29 ± 0.01 µM. Enriched tap water, purified laboratory water and bottled drinking water, with a certified tungsten reference solution traceable to NIST, gave a recovery of 97.1%, 99.1% and 99.1% respectively (n = 4 in each case) and a dynamic range from 0.6 to 30 µM. This study was performed by means of a Lineweaver-Burk plot, showing a mixed kinetic inhibition.


Assuntos
Técnicas Biossensoriais , Tungstênio/isolamento & purificação , Água/química , Fosfatase Alcalina/antagonistas & inibidores , Fosfatase Alcalina/química , Ácido Ascórbico/análogos & derivados , Ácido Ascórbico/química , Carbono/química , Enzimas Imobilizadas , Ouro/química , Limite de Detecção , Nanopartículas Metálicas/química , Soluções/química , Tungstênio/química
5.
Sensors (Basel) ; 14(5): 8203-16, 2014 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-24811076

RESUMO

A novel amperometric biosensor for the determination of Al(III) based on the inhibition of the enzyme acetylcholinesterase has been developed. The immobilization of the enzyme was performed on screen-printed carbon electrodes modified with gold nanoparticles. The oxidation signal of acetylthiocholine iodide enzyme substrate was affected by the presence of Al(III) ions leading to a decrease in the amperometric current. The developed system has a detection limit of 2.1 ± 0.1 µM for Al(III). The reproducibility of the method is 8.1% (n = 4). Main interferences include Mo(VI), W(VI) and Hg(II) ions. The developed method was successfully applied to the determination of Al(III) in spiked tap water . The analysis of a certified standard reference material was also carried out. Both results agree with the certified values considering the respective associated uncertainties.


Assuntos
Acetilcolinesterase/química , Alumínio/análise , Técnicas Biossensoriais/instrumentação , Condutometria/instrumentação , Ouro/química , Nanopartículas Metálicas/química , Água/química , Alumínio/química , Inibidores da Colinesterase/análise , Inibidores da Colinesterase/química , Desenho de Equipamento , Análise de Falha de Equipamento , Nanopartículas Metálicas/ultraestrutura , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Soluções
6.
Sensors (Basel) ; 14(2): 3756-67, 2014 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-24569772

RESUMO

A chronoamperometric method for vanadium ion determination, based on the inhibition of the enzyme alkaline phosphatase, is reported. Screen-printed carbon electrodes modified with gold nanoparticles were used as transducers for the immobilization of the enzyme. The enzymatic activity over 4-nitrophenyl phosphate sodium salt is affected by vanadium ions, which results in a decrease in the chronoamperometric current registered. The developed method has a detection limit of 0.39 ± 0.06 µM, a repeatability of 7.7% (n = 4) and a reproducibility of 8% (n = 3). A study of the possible interferences shows that the presence of Mo(VI), Cr(III), Ca(II) and W(VI), may affect vanadium determination at concentration higher than 1.0 mM. The method was successfully applied to the determination of vanadium in spiked tap water.


Assuntos
Técnicas Biossensoriais/métodos , Vanádio/análise , Fosfatase Alcalina/metabolismo , Técnicas Biossensoriais/instrumentação , Eletrodos , Enzimas Imobilizadas , Ouro , Limite de Detecção , Nanopartículas Metálicas , Nitrofenóis/metabolismo , Compostos Organofosforados/metabolismo , Reprodutibilidade dos Testes , Água/análise
7.
Talanta ; 99: 737-43, 2012 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-22967618

RESUMO

The following paper describes the development of a screen-printed voltammetric pH-sensor based on graphite electrodes incorporating both internal indicator (i.e., phenanthraquinone) and reference species (i.e., dimethylferrocene). The key advantages of this type of system stem from its simplicity, low cost and ease of fabrication. More importantly, as opposed to conventional voltammetric systems where the height of the voltammetric peaks is taken into account to quantify the amount of a species of interest, here, the difference between the peak potential of the indicator species and the peak potential of the reference species is used. Thus, this measurement principle makes the electrochemical system presented here less dependent on the potential of the reference electrode (RE), as is often the case in other electrochemical systems. The developed system displays very promising performances, with a reproducible Super Nernstian response to pH changes and a lifetime of at least nine days.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...